Network Monitoring, Sniffer, Analyser network monitor analyser sniffer remote lan monitor, wireless analyser
Wireless analyser, remote lan testing
network monitor analyser sniffer
   

 Six-Channel Optical Fiber nTAP


Technical Specifications

Options

  • Single-mode (9/125)
  • Multimode (62.5/125)
  • Multimode (50/125)

Dimensions

Height (case)

1.72 in / 4.37 cm

Width (case)

17 in / 43.18 cm

Depth (case)

5.94 in / 15.09 cm

Height (faceplate)

1.72 in / 4.37 cm

Width (faceplate)

19 in / 48.26 cm

Wavelength Tolerance Ranges

850/1300 (Dual-window) Multimode

+/- 15 nanometers

850-nm Laser Multimode

+/- 15 nanometers

1310 or 1550 (Single-window)
Single-mode

+/- 10 nanometers

1310/1550 (Dual-window)
Single-mode

+/- 40 nanometers

Maximum Insertion Losses (dB)

Split Ratio

Multimode
(850/1300)

Single-mode
(1310-1550)

50/50

4.4/4.4

4.0/4.0

60/40

3.6/5.6

2.9/5.0

70/30

3.0/6.9

2.3/6.2

80/20

2.4/8.8

1.7/8.0

90/10

1.9/11.9

1.2/11.4

Supported Media

Interface

Multimode

Single-mode

Link A / Link B (link under test)

850-nm, 1000BaseSX

1310-nm, 1000BaseLX

Optical Analyzer Interface

SC connector
62.5/125µm Fiber
50/125µm Fiber

SC connector
9/125µm Fiber

Environmental Requirements

Specification

Operational Range

Temperature range (operating)

-40° to +176° (F) / -40° to +80° (C)

Temperature range (storage)

-40° to +185° (F) / -40° to +85° (C)

Ambient Humidity

90% (non-condensating)


 